Packet capture and ProxySG system times are out of sync


<< Back to Knowledge Search

Solution

Overview

Packet capture time stamps are nearly 30 seconds later than ProxySG system time.

When we take a PCAP file on SG, its timestamps are off against ProxySG's system clock, sometimes over 30 sec.

 

Cause
Resolution
This problem only occurs in multi core CPU platform, like ProxySG900.
In order to solve this problem, SGOS must be upgraded to appropriate version as below.
Later 5.4.12.1
Later 5.5.11.1
Later 6.2.11.2
Later 6.3.5.1
 
Workaround
Additional Information
Bug Number
InQuira Doc IdKB5054
Attachment

Article Feedback

Hide Properties
First Published      10/01/2014
Last Modified      10/01/2014
Last Published      10/01/2014
Article Audience
Product      ProxySG
Software      SGOS 5
Article Number      000012493
Summary     
Was this helpful?
Comments:
 
Previous MonthNext Month
SunMonTueWedThuFriSat