Session Monitor bin cannot be synchronized after the Session Monitor service or proxy is restarted


<< Back to Knowledge Search

Solution

Overview

Session Monitor bin cannot be synchronized after the Session Monitor service or proxy is restarted.

The following errors are reported in the session monitor log: "Error parsing incoming bin entry during bin transfer", and "invalid IP address type".

Cause
Resolution

This defect, B#175124, was fixed :

- SG 6.2.8.3

- SG 6.2.9.1 and newer SG 6.2.x versions

- SG 6.3.3.1 and newer SG 6.3.x versions

 

SG 6.4 and newer SG 6.x versions are not affected by this.

Workaround
Additional Information
Bug Number
InQuira Doc IdKB5041
Attachment

Article Feedback