What SNMP traps can Director send?


<< Back to Knowledge Search

Solution

Overview

The below is by no means a complete list of Bluecoat Director SNMP Object Identifiers ( O.I.D)  as I have left out the more generic ones, and have only placed the more interesting ones here.  As you will note, most of the below OIDS relate to registered SG devices, and not the Director device itself.

NOTE: This was taken from the clear text MIB file named - sgme55.mibs available for download off of the Bluecoat website here- 510 MIBS

O.I.D.Description
1.3.6.1.4.1.3417.3.1.1.1The IPaddr or hostname of the SG.
1.3.6.1.4.1.3417.3.1.1.2The serial number of the SG
1.3.6.1.4.1.3417.3.1.1.3The Director ID of the SG
1.3.6.1.4.1.3417.3.1.1.4The Director name of the SG
1.3.6.1.4.1.3417.3.1.2.1An SG has been newly added to Director.
1.3.6.1.4.1.3417.3.1.2.2An SG has been deleted from Director.
1.3.6.1.4.1.3417.3.1.2.3An SG has transitioned to the CONNECTED state.
1.3.6.1.4.1.3417.3.1.2.4An SG has transitioned to the DISCONNECTED state
1.3.6.1.4.1.3417.3.1.2.5An SG has transitioned to the OK state
1.3.6.1.4.1.3417.3.1.2.6An SG has transitioned to the WARNING state
1.3.6.1.4.1.3417.3.1.2.7An SG has transitioned to the CRITICAL state.
1.3.6.1.4.1.3417.3.1.2.8An SG has been added via the auto-registration process
1.3.6.1.4.1.3417.3.1.2.9An SG's attempt to register via auto-registration process failed
Standby traps. 

1.3.6.1.4.1.3417.3.2.1.1

The IPaddr of this Director's partner in the redundant pair
1.3.6.1.4.1.3417.3.2.1.2This Director's partner's configured Primary.
1.3.6.1.4.1.3417.3.2.2.1.1.1Cannot find my Standby Partner
1.3.6.1.4.1.3417.3.2.2.1.1.2Found my Partner
1.3.6.1.4.1.3417.3.2.2.2.1.1I have been told to be a Primary partner
1.3.6.1.4.1.3417.3.2.2.2.1.2I have been told to be a Secondary partner
1.3.6.1.4.1.3417.3.2.2.2.1.3I have been told to operate standalone.
1.3.6.1.4.1.3417.3.2.2.2.1.4I have been told to become active.
1.3.6.1.4.1.3417.3.2.2.3.1.1A sync from primary has failed.
1.3.6.1.4.1.3417.3.2.2.3.1.2A sync was failing, but now is working
1.3.6.1.4.1.3417.3.2.2.3.2.1I was running Active Primary but found someone else was, so backing off.
  

NOTE: There are no plans for Director to support SNMP version 3.  As it stands now, it only supports SNMP version 2.

 Links to other articles:

For an explaination of what a OID is, see WIKI SITE

For details on what command line commands are available for Director, see 000014637

For details on how to create backups, profiles and an overlay file on Director, see 000010276

Cause
Resolution
Workaround
Additional Information
Bug Number
InQuira Doc IdFAQ1655
Attachment

Article Feedback

Hide Properties
First Published      10/01/2014
Last Modified      10/01/2014
Last Published      10/01/2014
Article Audience
Product      Director 510
Software      SGME 5.5
Topic      Configuration / WUI / CLI, Director Jobs, Errors / Event Logs / Alerts
Article Number      000015533
Summary     
Was this helpful?
Comments:
 
Previous MonthNext Month
SunMonTueWedThuFriSat